icsa-26-125-01
MEDIUM CVSS 4.4 csaf_cisa
Description
Hitachi Energy is aware of a vulnerability that affects the Hitachi Energy PCM600 product versions listed in this document. An attacker successfully exploiting this vulnerability can impact integrity of the product. Please refer to the Recommended Immediate Actions for information about the mitigation/remediation.
Timeline
- Published
- 2026-04-28 00:00 UTC
- Last Modified
- 2026-10-29
CVSS Details
CVSS details not available.
Affected Products
No product information available.
Weaknesses (CWE)
References
No references available.
Linked Vulnerabilities
No linked vulnerabilities found.
{
"document": {
"acknowledgments": [
{
"organization": "Hitachi Energy Internal Team"
}
],
"aggregate_severity": {
"namespace": "https://www.first.org/cvss/specification-document",
"text": "MEDIUM"
},
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://www.cisa.gov/news-events/news/traffic-light-protocol-tlp-definitions-and-usage"
}
},
"lang": "en-US",
"notes": [
{
"category": "summary",
"text": "Hitachi Energy is aware of a vulnerability that affects the Hitachi Energy PCM600 product versions listed in this document. An attacker successfully exploiting this vulnerability can impact integrity of the product. Please refer to the Recommended Immediate Actions for information about the mitigation/remediation.",
"title": "Summary"
},
{
"category": "legal_disclaimer",
"text": "The information in this document is subject to change without notice and should not be construed as a commitment by Hitachi Energy. Hitachi Energy provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall Hitachi Energy or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hardware or software described in this document, even if Hitachi Energy or its suppliers have been advised of the possibility of such damages. This document and parts hereof must not be reproduced or copied without written permission from Hitachi Energy and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose. All rights to registrations and trademarks reside with their respective owners.",
"title": "Notice"
},
{
"category": "general",
"text": "For additional information and support please contact your product provider or Hitachi Energy service organization. For contact information, see https://www.hitachienergy.com/contact-us/ for Hitachi Energy contact-centers.",
"title": "Support"
},
{
"category": "general",
"text": "It is highly recommended to deploy the product following the “PCM600 3.1 Cyber Security Deployment Guideline” document. Customers should maintain their systems with products running on supported versions and follow maintenance releases.\nRecommended security practices and firewall configurations can help protect a process control network from attacks that originate from outside the network. Such practices include that process control systems are physically protected from direct access by unauthorized personnel, have no direct connections to the Internet, and are separated from other networks by means of a firewall system that has a minimal number of ports exposed, and others that have to be evaluated case by case. Process control systems should not be used for Internet surfing, instant messaging, or receiving e-mails. Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system.",
"title": "General Mitigation Factors"
},
{
"category": "other",
"text": "Energy",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Switzerland",
"title": "Company headquarters location"
},
{
"category": "details",
"text": "SSVCv2/E:N/A:N/2026-10-27T13:01:47Z/",
"title": "SSVC"
},
{
"category": "legal_disclaimer",
"text": "This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy).",
"title": "Legal Notice and Terms of Use"
},
{
"category": "other",
"text": "This ICSA is a verbatim republication of Hitachi Energy PSIRT 8DBD000239 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Hitachi Energy PSIRT directly for any questions regarding this advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory icsa-26-125-01 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2026/icsa-26-125-01.json"
},
{
"category": "self",
"summary": "[1] Hitachi Energy Notification for Industrial Control Systems Cybersecurity Best Practices",
"url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000235&LanguageCode=en&DocumentPartId=&Action=Launch"
},
{
"category": "self",
"summary": "SharpZip Directory Traversal Vulnerability in Hitachi Energy PCM600",
"url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000239&LanguageCode=en&DocumentPartId=&Action=launch"
},
{
"category": "self",
"summary": "ICS Advisory icsa-26-125-01 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-125-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/news-events/ics-alerts/ics-alert-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/news-events/news/targeted-cyber-intrusion-detection-and-mitigation-strategies-update-b"
}
],
"title": "Hitachi Energy PCM600 (Update A)",
"tracking": {
"current_release_date": "2026-10-29T06:00:00.000000Z",
"generator": {
"date": "2026-10-27T14:37:44.165827Z",
"engine": {
"name": "CISA CSAF Generator",
"version": "1.5.0"
}
},
"id": "ICSA-26-125-01",
"initial_release_date": "2026-04-28T00:00:00.000000Z",
"revision_history": [
{
"date": "2026-04-28T00:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "Initial public release"
},
{
"date": "2026-05-05T06:00:00.000000Z",
"legacy_version": "Additional Release 1",
"number": "2",
"summary": "CISA Republication - Initial CISA Republication of Hitachi Energy 8DBD000239 advisory"
},
{
"date": "2026-10-27T00:00:00.000000Z",
"legacy_version": "Additional Release 2",
"number": "3",
"summary": "Remediation released in PCM600 v3.1 SP4 on 16-09-2026"
},
{
"date": "2026-10-29T06:00:00.000000Z",
"legacy_version": "Latest Updated CISA Republication",
"number": "4",
"summary": "CISA Republication update based on Hitachi Energy PSIRT 8DBD000239 advisory"
}
],
"status": "final",
"version": "4"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:PCM600_Legacy/<=2.11",
"product": {
"name": "PCM600 Legacy Version 2.11 and earlier",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "PCM600 Legacy"
},
{
"branches": [
{
"category": "product_version",
"name": "3.0",
"product": {
"name": "PCM600 3.0",
"product_id": "CSAFPID-0002"
}
},
{
"category": "product_version",
"name": "3.0_HF1",
"product": {
"name": "PCM600 3.0 HF1",
"product_id": "CSAFPID-0003"
}
},
{
"category": "product_version",
"name": "3.0_HF2",
"product": {
"name": "PCM600 3.0 HF2",
"product_id": "CSAFPID-0004"
}
},
{
"category": "product_version",
"name": "3.0_HF3",
"product": {
"name": "PCM600 3.0 HF3",
"product_id": "CSAFPID-0005"
}
},
{
"category": "product_version",
"name": "3.1",
"product": {
"name": "PCM600 3.1",
"product_id": "CSAFPID-0006"
}
},
{
"category": "product_version",
"name": "3.1_SP1",
"product": {
"name": "PCM600 3.1 SP1",
"product_id": "CSAFPID-0007"
}
},
{
"category": "product_version",
"name": "3.1_SP2",
"product": {
"name": "PCM600 3.1 SP2",
"product_id": "CSAFPID-0008"
}
},
{
"category": "product_version",
"name": "3.1_SP3",
"product": {
"name": "PCM600 3.1 SP3",
"product_id": "CSAFPID-0009"
}
},
{
"category": "product_version",
"name": "3.1_SP4",
"product": {
"name": "PCM600 3.1 SP4",
"product_id": "CSAFPID-0010"
}
}
],
"category": "product_name",
"name": "PCM600"
}
],
"category": "vendor",
"name": "Hitachi Energy"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2018-1002208",
"cwe": {
"id": "CWE-22",
"name": "Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')"
},
"notes": [
{
"category": "description",
"text": "SharpZipLib before 1.0 RC1 is vulnerable to directory traversal, allowing attackers to write to arbitrary files via a ../ (dot dot slash) in a Zip archive entry that is mishandled during extraction. This vulnerability is also known as 'Zip-Slip'."
}
],
"product_status": {
"fixed": [
"CSAFPID-0010"
],
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009"
],
"recommended": [
"CSAFPID-0010"
]
},
"references": [
{
"category": "external",
"summary": "NVD - CVE-2018-1002208",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2018-1002208"
},
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-1002208"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/22.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:N/I:H/A:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Please see the PCM600 Legacy Versions section below",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Ensure that Chapter 4 of Cyber Security Deployment Guideline - 1MRK505410 has been followed during the deployment. Ensure that no default credentials are in use. In case of exceptions, please ensure they have been mitigated with adequate countermeasures.",
"product_ids": [
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009"
]
},
{
"category": "vendor_fix",
"details": "Update to PCM600 3.1 SP4",
"product_ids": [
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 4.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009"
]
}
],
"title": "CVE-2018-1002208"
}
]
}